Pinout Values and Diagnostic Parameters
DOOR LOCK: WIRELESS DOOR LOCK CONTROL SYSTEM:
TERMINALS OF ECU
1. INSPECT INTEGRATION RELAY
(a) Disconnect the I12 relay connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance:
If the result is not as specified, there may be a malfunction on the wire harness side.
(c) Reconnect the connector.
(d) Measure the voltage according to the value(s) in the table below.
Standard voltage:
If the result is not as specified, the integration relay may have a malfunction.
2. INSPECT INSTRUMENT PANEL J/B (INTEGRATION RELAY)
(a) Disconnect the connectors IA, IB, ID, IF, IH and IJ the instrument panel J/B.
(b) Measure the voltage and resistance according to the value(s) in the table below.
Standard :
If the result is not as specified, there may be a malfunction on the wire harness side.
(c) Reconnect the connectors.
(d) Measure the voltage according to the value(s) in the table below.
Standard voltage:
If the result is not as specified, the integration relay or instrument panel J/B assembly may have a malfunction.