Console Lamp: Testing and Inspection
LIGHTING: PERSONAL LIGHT ASSEMBLY: INSPECTION
INSPECTION
1. INSPECT PERSONAL LIGHT ASSEMBLY (w/ Sliding Roof)
(a) Measure the resistance according to the value(s) in the table below.
Standard resistance:
(b) Connect the positive (+) lead from the battery to terminal 1 and the negative (-) lead to terminal 3, then check that the illumination comes on when switch operation is ON position.
2. INSPECT PERSONAL LIGHT ASSEMBLY (w/o Sliding Roof)
(a) Measure the resistance according to the value(s) in the table below.
Standard resistance:
(b) Connect the positive (+) lead from the battery to terminal 1 and the negative (-) lead to terminal 6, then check that the illumination comes on when switch operation is ON position.