Camshaft Position Sensor: Testing and Inspection
INSPECTIONINSPECT CAMSHAFT POSITION SENSOR
Using an ohmmeter, measure the resistance between the terminals.
Resistance:
At cold: 835 to 1,400 ohms
At hot: 1,060 to 1,645 ohms
NOTE: Cold and Hot mean the temperature of the coils themselves. Cold is from -10 °C (14 °F) to 50 °C (122 °F) and Hot is from 50 °C (122 °F) to 100 °C (212 °F).
HINT: If the resistance is not as specified, replace the camshaft position sensor.