Variable Induction Control Valve: Testing and Inspection
INSPECTIONINSPECT INTAKE AIR CONTROL VALVE
Inspection procedure when applying voltage between the terminals:
Apply battery voltage between terminals 4 (IAC+) and 5 (IAC-) of the intake air control valve. The actuator should continue to keep the valve open.