Variable Valve Timing Actuator: Testing and Inspection



CAMSHAFT TIMING OIL CONTROL VALVE ASSY
Resistance inspection.

Using an ohmmeter, measure the resistance between the terminals.

Resistance: 6.9 - 7.9 Ohm at 20 °C (68 °F)







Movement inspection.

Connect the positive (+) lead from the battery to terminal 1 and negative (-) lead to terminal 2, and check the movement of the valve.

NOTE: Confirm the valve does not adhere.

HINT: Bad returning of the valve by entrance of foreign objects causes subtle pressure leak to the advanced direction. Then, DTC can be detected.