Heated Oxygen Sensor








INSPECT HEATER RESISTANCE OF HEATED OXYGEN SENSOR
a. Disconnect the oxygen sensor connector.
b. Using an ohmmeter, measure the resistance between the terminals HT and +B.

Resistance: 11 - 16 Ohm at 20 °C (68 °F)