Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Oxygen Sensor: Testing and Inspection

HEATED OXYGEN SENSOR

INSPECTION




1. INSPECT HEATER RESISTANCE OF HEATED OXYGEN SENSOR (Bank 1 Sensor 1)
a. Disconnect the oxygen sensor connector.
b. Using an ohmmeter, measure the resistance between the terminals +B and HT

Resistance: 11 - 16 Ohm at 20 °C (68 °F)

If the resistance is not as specified, replace the sensor.

Torque: 44 N.m (450 kgf.cm, 31 ft.lbf)

c. Reconnect the oxygen sensor connector.




2. INSPECT HEATER RESISTANCE OF HEATED OXYGEN SENSOR (Bank 1, Sensor 2)
a. Take out the floor carpet.
b. Disconnect the oxygen sensor connector.
c. Using an ohmmeter, measure the resistance between the terminals +B and HT.

Resistance: 11 - 16 Ohm at 20 °C (68 °F)

If the resistance is not as specified, replace the sensor.

Torque: 44 N.m (450 kgf.cm, 31 ft.lbf)

d. Reconnect the oxygen sensor connector.
e. Resistance the floor carpet.