Hybrid Drive Coolant Temperature Sensor: Testing and Inspection
INSPECTIONINSPECT WATER TEMPERATURE SWITCH
Using a ohmmeter and thermometer, check continuity between terminals.
Standard:
No continuity at 48 °C (118.4 °F) or less
Continuity at more than 55 °C (131 °F)