Inspection
INSPECTION1. REMOVE ECM
a. Remove the finish lower center panel.
b. Remove the 3 bolts, and disconnect the ECM.
c. Disconnect the 3 (M/T and 3 A/T)or 4 (4 A/T) ECM connectors.
d. Disconnect the 5 connectors from connectors on bracket.
e. Disconnect the heated oxygen sensor (bank 1 sensor 2) connector.
Terminals Of ECM (M/T And 3 A/T) - Connector View:
Terminals Of ECM (M/T And 3 A/T) - Pinouts (Part 1):
Terminals Of ECM (M/T And 3 A/T) - Pinouts (Part 2):
Terminals Of ECM (4 A/T) - Connector View:
Terminals Of ECM (4 A/T) - Pinouts (Part 1):
Terminals Of ECM (4 A/T) - Pinouts (Part 2):
2. INSPECT ECM
3. REINSTALL ECM
a. Connect the 3 (M/T and 3 A/T) or 4 (4 A/T) ECM connectors.
b. Connect the 5 connectors from connectors on bracket.
c. Connect the heated oxygen sensor (bank 1 sensor 2) connector.
d. Connect the ECM, and install the 3 bolts.
e. Install the finish lower center panel.