Component Inspection
INSPECTION
1. INSPECT SHIFT LOCK CONTROL UNIT ASSEMBLY
Using a voltmeter, measure the voltage at each terminal.
HINT: Do not disconnect the shift lock control unit assembly connector.
2. INSPECT SHIFT LOCK SOLENOID
a. Disconnect the solenoid connector.
b. Apply battery positive voltage between terminals 1 and 2.
Check that operation noise can be heard from the solenoid.
If the solenoid does not operate, replace the solenoid.