Intermittent Wiper Operation
INSPECT INTERMITTENT WIPER OPERATION
1. Turn the wiper switch to INT position.
2. Turn the intermittent time control switch to FAST position.
3. Connect the positive (+) lead from the battery to terminal 17 and the negative (-) lead to terminal 16.
4. Connect the positive (+) lead from the voltmeter to terminal 7 and the negative (-) lead to terminal 16, check that the meter needle indicates battery positive voltage.
5. After connecting terminal 2 to terminal 17, connect to terminal 16.
Then, check that the voltage rises from 0 V to battery positive voltage within the times, as shown in the table.
If operation is not as specified, replace the switch.