Ignition Cable: Testing and Inspection
HIGH-TENSION CORDS INSPECTION
1. REMOVE HIGH-TENSION CORDS
Disconnect the high-tension cords at the rubber boot.
Do not pull on the cords.
NOTICE: Pulling on or bending the cords may damage the conductor inside.
2. INSPECT HIGH-TENSION CORD RESISTANCE
Using an ohmmeter, measure the resistance.
Maximum resistance: 25 K ohms per cord
If the resistance is greater than maximum, check the terminals.
If necessary, replace the high-tension cord.
3. REINSTALL HIGH-TENSION CORDS