Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Component Tests and General Diagnostics


KNOCK SENSOR INSPECTION

1. REMOVE KNOCK SENSOR
(a) Disconnect the knock sensor connector.





(b) Using SST, remove the knock sensor. SST 09816-30010





2. INSPECT KNOCK SENSOR
Using an ohmmeter, check that there is no continuity between the terminal and body.
If there is continuity. replace the sensor.
3. REINSTALL KNOCK SENSOR
(a) Using SST, install the knock sensor. SST 09816-30010

Torque: 44 N.m (450 kgf.cm, 33 ft.lbf)

(b) Connect the knock sensor connector.