Knock Sensor: Testing and Inspection
KNOCK SENSOR INSPECTION
1. REMOVE KNOCK SENSOR
- Disconnect the knock sensor connector.
- Using SST, remove the knock sensor.
SST 09816-30010
2. INSPECT KNOCK SENSOR
- Using an ohmmeter. check that there is no continuity between the terminal and body.
- If there is continuity, replace the sensor.
3. REINSTALL KNOCK SENSOR
- Using SST, install the knock sensor.
SST 09816-30010
Torque: 44 N.m (450 Kgf.cm, 33 ft.lbf)
- Connect the knock sensor connector.