EGR Backpressure Transducer: Testing and Inspection
EGR VACUUM MODULATOR INSPECTION1. DISCONNECT VACUUM HOSES FROM EGR VACUUM MODULATOR
- Disconnect these vacuum hoses:
(1) Vacuum hose from P port
(2) Vacuum hose from Q port
(3) Vacuum hose from R port
2. INSPECT EGR VACUUM MODULATOR OPERATION
- Block ports P and R with your finger.
- Blow air into port Q, and check that the air passes through to the air filter side freely.
- Start the engine, and maintain speed at 3,500 rpm.
- Repeat the above test.
- Check that there is a strong resistance to air flow.
3. RECONNECT VACUUM HOSES TO EGR VACUUM MODULATOR
- Connect these vacuum hoses:
(1) Vacuum hose to P port
(2) Vacuum hose to Q port
(3) Vacuum hose to R port