Service Hints
D 7 DOOR LOCK ECU8-Ground: Always approx. 12 Volts
16-ground: Always continuous
1-Ground: Approx. 12 Volts with the ignition SW at ON position
2-Ground: Continuous with the driver's door open
15-Ground: Approx. 12 Volts with the ignition SW ON, and it remains at 12 Volts for 60 seconds after the ignition SW is turned OFF.
However, if a door is opened within this 60 secondperiod, voltage will drop to 0 Volts
D11 DOOR COURTESY SW LH
2-Ground: Continuous with the driver's door open
P16 POWER WINDOW SW RH
5-Ground: Approx. 12 Volts with the ignition SW ON, and it remains at 12 Volts for 60 seconds after the ignition SW is turned OFF.
However, if a door is opened within this 60 secondperiod, voltage will drop to 0 Volts
P13 POWER WINDOW MASTER SW AND DOOR LOCK CONTROL SW LH
6-Ground: Always continuous
9-Ground: Approx. 12 Volts with the ignition SW ON, and it remains at 12 Volts for 60 seconds after the ignition SW is turned OFF.
However, if a door is opened within this 60 secondperiod, voltage will drop to 0 Volts
3-Ground: Approx. 12 Volts with the ignition SW at ON position and the driver's SW at UP position
4-Ground: Approx. 12 Volts with the ignition SW at ON position and the driver's SW at DOWN or AUTO DOWN position
WINDOW LOCK SW
Open with the window lock SW at LOCK position