Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Variable Induction Control Solenoid: Testing and Inspection

VSV FOR ACIS INSPECTION






1. REMOVE V-BANK COVER AND EMISSION CONTROL VALVE SET.

2. REMOVE VSV.
- Disconnect the 2 vacuum hoses from the VSV.
- Remove the screw and VSV.

3. INSPECT VSV
- Inspect VSV for open circuit



- Using an ohmmeter, check that there is continuity between each terminal.

Resistance @ 20°C (68°F): 33 - 39 Ohms

- If there is no continuity, replace the VSV.

- Inspect VSV for ground



- Using an ohmmeter, check that there is no continuity between each terminal and the body.
- If there is continuity, replace the VSV.

- Inspect VSV operation



- Check that air flows from port E to the filter.



- Apply battery positive voltage across the terminals.
- Check that air flows from port E to port F. If operation is not as specified, replace the VSV.

4. REINSTALL VSV.
- Install the VSV with the screw.
- Connect the 2 vacuum hoses to the VSV.

5. REINSTALL EMISSION CONTROL VALVE SET.
6. REINSTALL V-BANK COVER.