Variable Induction Control Solenoid: Testing and Inspection
VSV FOR ACIS INSPECTION1. REMOVE V-BANK COVER AND EMISSION CONTROL VALVE SET.
2. REMOVE VSV.
- Disconnect the 2 vacuum hoses from the VSV.
- Remove the screw and VSV.
3. INSPECT VSV
- Inspect VSV for open circuit
- Using an ohmmeter, check that there is continuity between each terminal.
Resistance @ 20°C (68°F): 33 - 39 Ohms
- If there is no continuity, replace the VSV.
- Inspect VSV for ground
- Using an ohmmeter, check that there is no continuity between each terminal and the body.
- If there is continuity, replace the VSV.
- Inspect VSV operation
- Check that air flows from port E to the filter.
- Apply battery positive voltage across the terminals.
- Check that air flows from port E to port F. If operation is not as specified, replace the VSV.
4. REINSTALL VSV.
- Install the VSV with the screw.
- Connect the 2 vacuum hoses to the VSV.
5. REINSTALL EMISSION CONTROL VALVE SET.
6. REINSTALL V-BANK COVER.