Oxygen Sensor: Testing and Inspection
OXYGEN SENSOR INSPECTION
1. Warm Up Engine
Allow the engine to reach normal operating temperature.
2. Inspect Feedback Voltage
Connect the positive (+) probe of a voltmeter to terminal VF of the data link connector 1, and negative (-) probe to terminal E1. Perform the test as follows: