Air Temperature Sensor ( Ambient / Intake ): Testing and Inspection
Intake Air Temperature Sensor Circuit:
NOTE: For most problems a circuit test is the preferred method of inspection. For the circuit test for this component refer to the Non-Trouble Code Charts.
Component Tests and General Diagnostics
INTAKE AIR TEMPERATURE (IAT) SENSOR INSPECTION
1. Remove IAT Sensor
2. Inspect IAT Sensor and connector for damage.
3. Using an ohmmeter, measure the resistance between the terminals.
Resistance: Temperature
-20° C (-4° F) 10.0 - 20.0 k ohms
0° C (32° F) 4.0 - 7.0 k ohms
20° C (68° F) 2.0 - 3.0 k ohms
40° C (104° F) 0.9 - 1.3 k ohms
60° C (140° F) 0.4 - 0.7 k ohms
80° C (176° F) 0.2 - 0.4 k ohms