ECM Inspection
ECM INSPECTIONNOTE: The MFI circuit can be checked by measuring the resistance and voltage at the wiring connectors of the ECM.
1. REMOVE FLOORMAT BRACKET
2. PREPARATION
(a) Disconnect the 3 connectors from the ECM.
(b) Remove the locks as shown in the illustration so that the tester probe(s) can easily come in.
CAUTION: Pay attention to sections "A" and "B" in the illustration which can easily broken.
(c) Reconnect the 3 connectors to the ECM.
3. INSPECT VOLTAGE OF ECM
(a) Turn the ignition switch ON.
(b) Measure the voltage between each terminal of the wiring connectors.
NOTE:
- Perform all voltage measurements with the connectors connected.
- Verify that the battery voltage is 11 V or more when the ignition switch is ON.
Except 7A-FE Automatic Transaxle:
7A-FE With Automatic Transaxle:
Connector View/Terminal I.D.
Standard Voltage Values
4. INSPECT RESISTANCE OF ECM
(a) Turn the ignition switch OFF.
(b) Disconnect the 3 connectors from the ECM.
(c) Measure the resistance between each terminal of the wiring connectors.
CAUTION:
- Do not touch the ECM terminals.
- The tester probe should be inserted in the wiring connector from the wiring side.
Standard Resistance Values
5. INSTALL ECM
(a) Insert the ECM to the bracket.
(b) Connect the 3 connectors to the ECM.
6. INSTALL FLOORMAT BRACKET