Fuel Pump Relay: Testing and Inspection
CIRCUIT OPENING RELAY INSPECTION1. Remove Circuit Opening relay
The Circuit Opening Relay Is Mounted On The ECM, In The Lower/Center Area Of The Dash:
Refer to the included image for component removal information.
2. Inspect Circuit Opening relay
(a) Inspect relay continuity
- Using and ohmmeter, check that there is continuity between terminals STA and E1.
- Check that there is continuity between terminals +B and FC.
- Check that there is no continuity between terminals + B and FP.
^ If continuity is not as specified, replace the relay.
(b) Inspect relay operation
- Apply battery voltage across terminals STA and E1.
- Using an ohmmeter. check that there is continuity between terminals +B and FP.
- Apply battery voltage across terminals +B and FC.
- Check that there is continuity between terminals +B and FP.
^ If operation is not as specified, replace the relay.
3. Reinstall Circuit Opening relay