Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Main Oxygen Sensor

OXYGEN SENSOR INSPECTION
1. Allow the engine to warm up to normal operating temperature
2. Inspect Feedback Voltage.



Connect the positive (+) tester probe of a voltmeter to terminal VF1 of the data link connector 1 (DLC1), and negative (-) tester probe to terminal E1. Perform the test as described in the following image.

HINT: Use Special Service Tool (SST) when connecting between terminals TE1 and E1 of the DLC1. (SST 09843-18020)

Use a jumper wire when connecting between terminals TE1 and E1 of the DLC1.: