Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Variable Induction Control Actuator: Testing and Inspection

INSPECTION





1. With 26.7 kPa (7.9 in Hg) of vacuum applied to the Actuator, check that the Actuator rod moves.
2. One minute after applying the vacuum in step 1, check that the actuator rod does not return. If the operation is not as specified, replace the intake air control valve.