Manifold Pressure/Vacuum Sensor: Testing and Inspection
Vacuum Sensor Circuit:
Vacuum Sensor Inspection - Power Source:
Inspect Power Source Voltage Of Vacuum Sensor
- Disconnect the vacuum sensor connector.
- Turn the ignition switch ON.
- Using a voltmeter, measure the voltage between terminals VCC and E2 of the vacuum sensor connector.
Voltage: 4-6V
- Reconnect the vacuum sensor connector.
Vacuum Sensor Inspection - Signal Output:
Inspect Power Output Of Vacuum Sensor
- Turn the ignition switch ON.
- Disconnect the vacuum hose on the air intake chamber side.
- Connect a voltmeter to terminals PIM and E2 of the ECM, and measure the output voltage under ambient atmospheric pressure.
- Apply vacuum to the vacuum sensor in 13.3 kPa (100 mmHg, 3.94 in.Hg) segments to 66.7 kPa (500 mmHg, 19.69 in.Hg).
- Measure the voltage drop for each segment.
Voltage Drop Specifications:
Voltage Drop Specifications