Ignition Cable: Testing and Inspection
Plug Wire Removal:
Disconnect High-tension Cords From Spark Plugs
- Disconnect the high-tension cords at the rubber boot.
NOTICE: Pulling on or bending the cords may damage the conductor inside.
Remove IIA Cap Without Disconnecting High-tension Cords
Checking Wire Resistance:
Inspect High-tension Cord Resistance
- Using an ohmmeter, measure the resistance without disconnecting the IIA cap.
Maximum resistance: 25 k ohms per cord
- If the resistance is greater than maximum, check the terminals.
- If necessary, replace the high-tension cord and/ or IIA cap.