Distributor: Testing and Inspection
DISTRIBUTOR INSPECTION1. INSPECT AIR GAP
Using a feeler gauge, measure the gap between the signal rotor and pickup coil projection.
Air gap: 0.2 - 0.4 mm (0.008 - 0.016 in.)
If the air gap is not as specified, replace the distributor.
2. INSPECT PICKUP COIL RESISTANCE
Using an ohmmeter, measure the resistance between terminals.
G1 pickup coil resistance (G1 to G (-)): 140 - 180 ohms
G2 pickup coil resistance (G2 to G (-)): 140 - 180 ohms
NE pickup coil resistance (NE to G (-)): 140 - 180 ohms
If the resistance is not as specified, replace the distributor.