Ignition Timing: Specifications
IGNITION TIMING AT IDLECheck connector terminal condition [1]
Connected 10° BTDC
Disconnected 14 - 19° BTDC
[1] Terminals T and E1 of check connector are short-circuited with service wire (jumper wire) to check and adjust base timing.