Thermo Time Switch: Specifications

COLD START INJECTOR TIME SWITCH

Resistance Between Terminals:
STA - STJ
Below 30°C (86°F) 20 - 40 ohms
Above 40°C (104°F) 40 - 60 ohms

STA - Ground 20 - 80 ohms