Vacuum Reservoir: Service and Repair
VIS Vacuum Tank Removal and InstallationRemoval
1. Remove the vacuum hose.
2. Remove the VIS solenoid.
3. Remove the VIS vacuum tank.
Installation
1. Installation should follow the removal procedure in the reverse order.
2. Install the VIS vacuum tank.
Tighten: Tighten the VIS vacuum tank retaining bolts to 7 - 9 N.m (62 - 80 lb-in.).