Thermostat (FA20/For Engine Coolant)
Installation1. Thermostat installation
(1) Install a new gasket to the thermostat.
(2) Install the thermostat to the water outlet.
2. Water outlet installation
(1) Install the water outlet with the two bolts.
Standard value:T=6.4Nm {65kgf-cm} {4.7ft-lbf}
3. Radiator outlet hose connection
(1) Align the marks marked when removing the hose, install the radiator outlet hose to the water outlet and secure the hose with the hose clamp.
4. Coolant (SUBARU Super Coolant) refill
5. Coolant (SUBARU Super Coolant) leakage check Testing and Inspection
6. Exhaust manifold installation