Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Removal and Replacement

Generator

REMOVAL
1. Remove the collector cover.
2. Disconnect the ground cable from battery.
3. Disconnect the connector and terminal B from the generator, and remove the harness cover from the collector cover bracket.






4. Remove the V-belts.
5. Remove the collector cover bracket.






6. Remove the generator.






INSTALLATION
Install in the reverse order of removal.

CAUTION: Check and adjust the V-belt tension.

Tightening torque: 25 N.m (2.5 kgf-m, 18.4 ft-lb)






Tightening torque:
T1: 6.4 N.m (0.7 kgf-m, 4.7 ft-lb)
T2: 25 N.m (2.5 kgf-m, 18.4 ft-lb)







Tightening torque: 16 N.m (1.6 kgf-m, 11.8 ft-lb)