Overhaul
Oil Flow Control Solenoid ValveDISASSEMBLY
1. Remove the two bolts which secure the oil return cover, and remove the oil return cover and gasket.
2. Remove the bolt which secures the oil flow control solenoid valve and remove the oil flow control solenoid valve.
ASSEMBLY
1. Install the oil flow control solenoid valve.
Tightening torque: 8 N.m (0.8 kgf.m, 5.9 ft.lb)
2. Apply liquid gasket to the two bolts which secure the oil return cover.
Liquid gasket: THREE BOND 1324 (Part No. 004403042) or equivalent
3. Install the oil return cover and gasket.
Tightening torque: 8 N.m (0.8 kgf.m, 5.9 ft.lb)
NOTE: Use a new gasket.