Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Blower Motor Unit Assembly

Blower Motor Unit Assembly

REMOVAL

1. Disconnect the battery ground cable from the battery.
2. Remove the instrument panel lower cover.
3. Remove the protect cover of ECM.






4. Disconnect the connectors of the intake door actuator and blower motor.
5. Remove the relay holder.
6. Loosen the bolt and nut to remove blower motor unit assembly.






INSTALLATION

Install in the reverse order of removal.

HEATER COOLING UNIT

Tightening torque: N.m (kgf.m, ft.lb)
T1: 5.0 (0.5, 3.7)
T2: 6.68 (0.7, 4.9)
T3: 7.5 (0.76, 5.5)


BLOWER MOTOR UNIT

Tightening torque: N.m (kgf.m, ft.lb)
T: 7.5 (0.76, 5.5)