Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Air Cleaner Housing: Service and Repair

Air Cleaner Case

REMOVAL
1. Remove the air intake duct.
2. Remove the air cleaner element.




3. Remove the bolts (A) and nuts (B) which secure the air cleaner case (front) to the body.
4. Remove the air cleaner case (front).

INSTALLATION
Install in the reverse order of removal.

Tightening torque:
Bolt: 6.0 N.m (0.61 kgf-m, 4.4 ft-lb)