Actuator Operation

Compulsory Valve Operation Check Mode

OPERATION




1. Prepare the Subaru Select Monitor kit.
2. Connect the diagnosis cable to Subaru Select Monitor.




3. Insert the cartridge to Subaru Select Monitor.




4. Connect the test mode connector (A) located at the lower portion of glove box.




5. Connect the Subaru Select Monitor to data link connector located in the lower portion of instrument panel (on the driver's side).

CAUTION: Do not connect the scan tools except for Subaru Select Monitor or OBD-II general scan tool.




6. Turn the ignition switch to ON (engine OFF) and turn Subaru Select Monitor switch to ON.
7. On the Main Menu display screen, select the {Each System Check} and press the [YES] key.
8. On the System Selection Menu display screen, select the {Engine} and press the [YES] key.
9. Press the [YES] key after the information of engine type has been displayed.
10. On the Engine Diagnosis display screen, select the {System Operation Check Mode} and press the [YES] key.
11. On the System Operation Check Mode display screen, select the {Actuator ON/OFF Operation} and press the [YES] key.
12. Select the desired compulsory actuator on the Actuator ON/OFF Operation display screen and press the [YES] key.
13. Pressing the [NO] key completes the compulsory operation check mode. The display will then return to the Actuator ON/OFF Operation screen.




- A list of support data is shown in the table.






NOTE:
- The parts will be displayed but not functional.
- For detailed operation procedure, refer to SUBARU SELECT MONITOR OPERATION MANUAL.