Thermostat: Testing and Inspection

INSPECTION:

Replace the thermostat if the valve does not close completely at an ambient temperature or if the following test shows unsatisfactory results.

Thermostat Testing:






- Immerse the thermostat and a thermometer in water.
- Raise water temperature gradually, and measure the temperature and valve lift when the valve begins to open and when the valve is fully opened.
- During the test, agitate the water for even temperature distribution.
- The measurement should be to the specification:
Starts to open:
EFC model: 83.5-86.5°C (182-188°F)

Fully open:
EFC model: 100°C (212°F)