Variable Induction Control Actuator: Service and Repair
Tumble Generator Valve ActuatorREMOVAL
RH SIDE
1. Release the fuel pressure.
2. Disconnect the ground cable from battery.
3. Open the fuel filler flap lid and remove the fuel filler cap.
4. Remove the intake manifold.
5. Disconnect the connector from tumble generator valve actuator RH.
6. Remove the tumble generator valve actuator RH.
LH SIDE
1. Release the fuel pressure.
2. Disconnect the ground cable from battery.
3. Open the fuel filler flap lid and remove the fuel filler cap.
4. Remove the secondary air pump.
5. Disconnect the connector from tumble generator valve actuator LH.
6. Remove the tumble generator valve actuator LH.
INSTALLATION
RH SIDE
Install in the reverse order of removal.
LH SIDE
Install in the reverse order of removal.