Remedy 14
1. A short circuit to ground may be indicated by the SRS lamp remaining On continuously when the ignition is switched On.2. A short circuit to battery positive may be indicated by the SRS lamp not lighting up at all for the first six seconds after the ignition is switched On. The continuous fault duration must be at least 20 seconds before the fault code is stored in memory.
3. Check cable 920A from pin 20 of electronic unit through pin 7 in connector H10-2 and on pin 6 of combined instrument. Also check cable 920 between pin 7 in connector H10-2 and pin 10 of test socket H10-3 for a short circuit to ground or battery positive terminal.