Fuel Pressure: Testing and Inspection
LH - Jetronic System:
1. Connect appropriate fuel pressure gauge to inlet of fuel injection manifold.
2. Energize fuel pump by connecting jumper wire from fuse #14 to fuse #22.
3. Read system pressure.
4. Disconnect jump wire, pressure should immediately drop to residual specification and maintain pressure for 10 minutes.