Door Window Glass - Proper Installation
88saab07FILE IN S.I. Man VOL. I
SEC. A-8 PG. 106
ISSUE: 04/88-1049
SUBJECT: INSTALLING DOOR WINDOW GLASS
APPLICATION: 900 CONVERTIBLE
If the door glass is replaced or the retainer has been removed from the glass for any reason, the retainer must be properly repositioned on the glass for correct window operation.
Measure off 329 mm from the rear of the glass (see drawing) to the hole identified in the retainer. Fit the retainer and be sure it grips the glass evenly and securely. If the retainer is not properly positioned or if the retainer is not secure the window may not operate correctly.