Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Ignition Coil Saturation

Fig. 77 Charging the Ignition Coil:





The rotor slots shield the Hall effect switch from the magnetic field, preventing voltage generation by the Hall switch, Fig. 77. The output module is energized, thereby closing the primary circuit, and the primary winding becomes saturated with voltage.