Functional Inspection
1. Disconnect injector electrical connectors, then loosen fuel injection assembly so that each injector may be placed in a six cubic inch (100 cc) container.
2. Operate fuel pump as described in steps 3 and 4 under ``Fuel Supply System.''
3. Apply 12 volts from outside source to each injector electrical connector and check for discharge of vaporized fuel into beaker.
4. Install injector fuel lines and injectors, then connect injector electrical connector.
5. Operate engine, then disconnect electrical connector from each injector. Engine speed should decrease.