All Gauges Inoperative
Tests 1 - 4:
Tests 5 - 9:
SYMPTOM
ALL GAUGES NOT OPERATING
POSSIBLE CAUSES
- Check fuses in the fuse block
- Attempt to communicate with the BCM
- Fused ignition switch output circuit open connector C2
- Attempt to communicate with the instrument cluster
- Fused ignition switch output circuit open (C1)
- Ground circuit open instrument cluster connector C1
- Ground circuit open instrument cluster connector C2
- Fused B(+) circuit open
- Instrument cluster