Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Testing For Open Circuits, High Resistance and Loose Terminals

Use an ohmmeter to check cables for opens, loose terminals or high resistance as follows:
1. Remove cable from spark plug.
2. Remove cable from the coil tower.
3. Connect the ohmmeter between the spark plug end terminal and the coil end terminal.
- Make sure ohmmeter probes are in good contact.
- Resistance should be within tolerance shown in the cable resistance chart.
- If resistance is not within tolerance, replace cable assembly. Test all spark plug cables in the same manner.

- If no problems are found, SEE Ignition System/System Diagnosis/Testing For Spark At Coil.

SECONDARY IGNITION CABLE RESISTANCE
Minimum Maximum
Cables #1 & #4 3,500 Ohms 4,900 Ohms
Cables #2 & #3 2,950 Ohms 4,100 Ohms