Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

No Fail Safe Code (No Shift Made)






Inspection Step 13


Description


No shift is made during operation. No fail safe code is output. In this case, a defective overdrive switch, Park/Neutral position switch, etc. are suspected.


Probable Cause of Trouble

- Defective overdrive switch
- Defective Park/Neutral position switch
- Defective power supply circuit
- Defective transaxle control module