Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Test Values For Timing




Test Values For Timing

Timing of inlet valve at 2 mm valve lift and new timing chain
Opens after TDC 20 ± 2 degrees CKA
closes after BDC 29.5 ± 2 degrees CKA

Timing of exhaust valve at 2 mm valve lift and new timing chain
Opens before BDC 29.3 ± 2 degrees CKA
closes before TDC 14 ± 2 degrees CKA