Preparing Glue Cartridge
References (WH), Commercially available tools
References (BR), Service products for repair
1 Remove cartridge for glazing from repair kit, place in cartridge heater unopened and switch on cartridge heater.
NOTE: Heat-up time at least 20 minutes.
Injury hazard
When clamping blade into multi-cutter and unclamping cuts can results when the tensioning wrench slips off or unintentionally switching on the multi-cutter.
Glass splinters can injure eyes and hands when cutting out bonded windows.
Rules of behavior/protective measures
- Clamp/unclamp blade only with air supply shut-off.
- Wear protective gloves.
- Wear protective goggles when cutting out windows.