Pneumatic Multiple Connector Test - Section 33
NOTE: The multiple connector was eliminated as of approx. 12/93
Preparation For Test:
1. Pry off all pneumatic lines from pneumatic multiple connector (using a 7 mm open end wrench.)
2. Plug all connections on the upper side of the pneumatic multiple connector with plugs (part no. 124 805 02 44).
3. Connect vacuum/pressure tester to the bottom side of the pneumatic multiple connector to test the individual connections ZV, SRU, OSL.
Parts Required for Test:
10 Plugs 124 805 02 44
1 Connector 129 805 04 44
NOTES: The connections on the PSE control module and pneumatic multiple connector are marked with their German acronyms. In other words:
ZV (German) = CL (English),
SRU (German) = MVA (English),
OSL (German) = OSB (English).