Testing Battery Capacity (Load Test)
Preliminary work:
Checking state of charge, Check Condition of Battery
Quiescent current retention unit
disconnect, connect.
Battery
disconnect, reconnect. Disconnecting and Connecting Battery
Battery
remove, install.
Electrolyte density
measure, min. 1.24 kg/dm cu; if electrolyte density <1.24 kg/dm cu, charge battery
NOTE: On vehicles with two batteries both batteries must be removed and tested separately.
Load test at 20 °C
perform.
Capacity/Ah Load current/A
74 230
100 300
Battery minimum voltage
check, specification after 10 seconds approx. 10 V or >10 V.
If specified value is not reached, renew battery.
If specified value is reached, charge battery.
Electrolyte density
measure, specification 1.28 kg/dm cu.
Commercially available testers
Acidimeter e.g. Hazet
Volt/ampere tester with load resistor e.g. Hermann, Electronic
Quiescent current retention unit e.g. Hans Zeheter CMP 12.2