Without A/C
Removal
1 Remove cover on air intake Procedures
2 Pull vacuum line from heater valve.
3 Unscrew screws on cover.
4 Pull sealing profile (A) from parting wall and unscrew fastening screws.
5 Pull parting wall in upper range in forward direction and remove cover on blower in upward direction.
6 Loosen cable straps on connecting cable and pull off plug connection.
7 Unscrew screws on blower and remove blower.
Installation
8 For installation proceed vice versa.